Please use this identifier to cite or link to this item: http://adhlui.com.ui.edu.ng/jspui/handle/123456789/2254
Title: Evaluation of saliva-based diagnostic test kit for routine detection of antibodies to HIV
Authors: Akanmu*, A.S
Akinsete, I
Adesemoye, E.F
Okany, C.C
Keywords: Saliva
Negative Predictive Value
Specificity
Sensitivity
Positive Predictive Value
HIV-antibodies
Issue Date: 2001
Publisher: CCOLLEGE OF MEDICINE
Citation: Afr J Med. med. Sci (2001) 30, 305-308
Abstract: The study was carried out to determine the reliability of a saliva based test kit for routine detection of HIV antibodies. 150 paired plasma and saliva samples were collected from 50 patients who were known to be positive for HIV-! and 100 others whose HIV scrostatus were previously unknown. All the plasma samples were tested for HIV antibodies using Novopath Immunoblot Technique (as the gold standard), Wellcozyme (Murex) ELISA, Latex Agglutination Test (Capillus) and SeroCard Kit. The saliva samples were screened for HIV antibodies using SalivaCard Test Kit. All the 50 known positive patients tested positive when rctestcd with immunoblot and 9 of 100 whose scrostatus were unknown also tested positive giving a total of 59 positive results and 91 negative results. Of the 59 positive results, 59, 57, 58 and 47 were correctly identified as true positives by Wcllcozymc, Capillus, SeroCard and SalivaCard respectively. Of the 91 negatives, 90,91,90 and 85 were correctly identified as true negatives respectively. Sensitivities in the same order were 100%, 97%, 98.3% and 79.7% whilst specificities were 98.9%, 100%, 98.9% and 97.8%. Whereas evaluation parameters for Wellcozyme, Capillus and SeroCard test kits met the criteria for licensure of a test kit as a routine test method for HIV antibody detection, the SalivaCard values fell far short of the stipulated criteria. The Sensitivity, Test Efficiency and Positive Predictive Values of 79.7%, 88% and 67.8% respectively obtained for SalivaCard arc too low and the test kit cannot be recommended for routine use as HIV antibody detection kit
Description: Article
URI: http://adhlui.com.ui.edu.ng/jspui/handle/123456789/2254
ISSN: 1116-4077
Appears in Collections:African Journal of Medicine and Medical Sciences

Files in This Item:
File Description SizeFormat 
Akanmu et al _Evalution_2001.pdfArticle10.47 MBAdobe PDFView/Open


Items in COMUI (ADHL) are protected by copyright, with all rights reserved, unless otherwise indicated.