Please use this identifier to cite or link to this item:
http://adhlui.com.ui.edu.ng/jspui/handle/123456789/1929
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | AROWOJOLU, A.O | - |
dc.contributor.author | OTOLORIN, E.O. | - |
dc.contributor.author | LADIPO, O A. | - |
dc.date.accessioned | 2023-02-09T11:37:00Z | - |
dc.date.available | 2023-02-09T11:37:00Z | - |
dc.date.issued | 1995-03 | - |
dc.identifier.citation | Afr. J. Med. med. Sci. (1995) 24(1): 27-31. | en_US |
dc.identifier.issn | 1116-4077 | - |
dc.identifier.uri | http://adhlui.com.ui.edu.ng/jspui/handle/123456789/1929 | - |
dc.description | Article | en_US |
dc.description.abstract | An evaluation of the performances of copper T 380A (TCU 380A) and multiload copper 375/250 (MLCU 375/250) intrauterine contraceptive devices (IUCDS) was carried out at University College Hospital, Ibadan, Nigeria (UCH) in a clinical comparative trial. The IUCDS showed similar low vent rates at one year of continuous use. The difference in cumulative net probabilities for termination due to pelvic inflammatory disease was weakly significant at the sixth month of follow up with MLCU 250 having the highest rate. (TCU 380A-0%; MLCU 375-0% MLCU 250-3.1%; X*-6.0; P < 0.05). This significant difference disappeared by the twelfth month ofcontinuous use. Likewise, the difference in cumulative net probabilities for overall termination was significant at six months and insignificant at twelve months of follow up. The continuation rate after one year were 86%, 92% and 87% respectively for TCU 380A, MLCU 375 and MLCU 250. These rates were higher than 80% and 51% quoted for the previously available Lippes loop in the same environment! l^J. It was therefore concluded that the three IUCDS are comparable in performances in the first year of use and could be used at our family planning clinic or any other clinic in a similar setting. | en_US |
dc.description.sponsorship | College of Medicine | en_US |
dc.language.iso | en | en_US |
dc.publisher | SPECTRUM BOOKS LIMITED. | en_US |
dc.subject | Contraceptive devices | en_US |
dc.subject | Copper T 380A (TCU 380A) | en_US |
dc.subject | Multiload copper 375/250 (MLCU 375/250) | en_US |
dc.subject | Intrauterine contraceptive devices (IUCDS) | en_US |
dc.subject | Ibadan | en_US |
dc.title | Performances of copper T 380A and multiload copper 375/250 intrauterine contraceptive devices in a comparative clinical trial. | en_US |
dc.type | Article | en_US |
Appears in Collections: | African Journal of Medicine and Medical Sciences |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Arowojolu et al_Performance_1995.pdf | Article | 11.09 MB | Adobe PDF | View/Open |
Items in COMUI (ADHL) are protected by copyright, with all rights reserved, unless otherwise indicated.